Ultrasonik Hata Dedektörü
UTS-280
.
UTS-280 Ultrasonik Hata Dedektörü
Designation
Technical Data
Range of scanning (mm)
Range of scanning (mm): 0-10000
Steps: 2.5,5,10,20, 30,40,50,60,70,80,90, 100,150,200,
250, 300,350,400,450,500,600,700,800,900,1000,2000,3000,4000,
5000,6000,7000,8000,9000,10000
Adjusting step: 0.1mm (2.5 mm-99.9mm), 1mm (100mm-10000mm)
D-delay (ms)
D-delay (ms): -20-+3400
Steps:-20,-10,0.0,10,20,50,100,150,200,250,300,350,400,450,500, 600,700,800,900,1000,1500,2000,2500,3000,3400.
Adjusting steps: 0.1(-20ms-999.9ms), 1(1000ms-3400ms)
P-delay (ms)
P-delay: 0.0-99.99
Adjusting steps: 0.01
MTLVEL(m/s)
MTLVEL:1000-15000 10 fixed levels: 2260,2730,3080,3230,4700,5920,630012000,13000,14000,15000
Adjusting steps: 1
Working mode
Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission (transmission probe)
Frequency Range (MHz)
0.2-20
Gain adjustment (dB)
0-130
Adjusting step: 0.0, 0.1, 0.5, 1, 2, 6, 12
Reject
0%-80% of screen height, step: 1%
Vertical linear error
Vertical linear error is not more than 3%
Horizontal linear error
Not more than 0.2% in the scanning range
Sensitivity Leavings
≥62 dB
Dynamic range
≥34dB
Alarm
Three modes, i.e. forbidden wave, loss wave and auto
A-Scan display area
Full screen or local
A-Scan display freezing and de-freezing A-Scan filling
Data save
1000 A-Scan images (including setting of instrument)
Standard communication interface with PC
USB
Measuring unit
mm / inch
Battery
Li battery 7.4V 4800mAh
Power adaptor
Input 100V-240V / 50Hz-60Hz
Output 9VDC / 1.5A
Working temperature
-20°C – 50°C
Working humidity
20% – 90%
Port type
BNC / LEMO
Overall dimension (mm)
50 x 160 x238
Weight (kg)
1.0